Skip to content
LISEN BAUMER · Point Level Sensor
◎ EN
Request a quote

Installation

Choose a sensor location when pipes contain air slugs

A Point Level Sensor can give a useful empty-pipe indication when its location follows the actual drainage behavior.

4 10 月 2026 · 2 minute read

POINT LEVEL SENSOR / PRACTICAL ADVANTAGE

Use local detection where it represents the liquid path

A Point Level Sensor can give a useful empty-pipe indication when its location follows the actual drainage behavior. Careful placement helps distinguish a meaningful absence of liquid from brief air slugs. The benefit is a clearer control input with less dependence on excessive delay settings.

Define whether intermittent contact matters

Decide whether the goal is to detect a completely empty pipe, a short gas slug, loss of usable supply or a routine transition during startup. These are different tasks. A sensor at one location cannot by itself establish the flow condition throughout the piping system. Document which temporary states should be tolerated and which must trigger a response.

Inspect the physical layout

Review pipe slope, high points, low pockets, branch connections and nearby valves. A tip at the top of a pipe may lose liquid contact before the lower part drains, while a low pocket may remain wet after useful flow has stopped. Neither observation is automatically wrong; the question is whether it represents the required control condition. Use drawings and controlled observation to select the location.

Use timing only after understanding the process

Damping can suppress short changes, but it also adds response delay. Determine the duration of normal gas slugs and the maximum acceptable delay for the event of concern. If those ranges overlap, no single timer setting resolves the design problem. The installation or sensing strategy may need to change. Include startup bypasses and reset logic in the same assessment.

Test the intended transitions

Record steady liquid, the representative intermittent condition, drain-down, refill and startup. Compare local tip contact with an independent observation of the process. Where a pump-protection role is proposed, involve the responsible process designer: a wet tip does not prove acceptable suction pressure or freedom from cavitation. Keep the final settings with the location drawing so maintenance does not unknowingly change the detection basis.

What to keep in the project record

  • Exact event to detect and normal transient conditions
  • Mounting position relative to pockets and branches
  • Permissible delay and startup logic
  • Evidence comparing sensor state with process behavior

Explore the Point Level Sensor advantages guide or compare the available sensor families for this duty.

Put this Point Level Sensor advantage to work

Compare the Lisen and Baumer Point Level Sensor families, prepare an application brief, or use the sensor selector to organize the next technical discussion.

References

Lisen technical reference — English summary of the supplied 2024-11-25 manual

Baumer CleverLevel LBFS datasheet — supplied reference, EN/2018-03-01

Technical guidance. Verify the current order-code documentation and your plant requirements before applying a recommendation.

Continue reading

LISEN · BAUMER

Put Point Level Sensor advantages to work in your process.

Tell us the medium, switching task, temperature, pressure and connection. We will help define the sensor family and installation package.

Request a quote
Contact on WhatsApp
滚动至顶部