Skip to content
LISEN BAUMER · Point detection
◎ EN
Request a quote

APPLICATION ENGINEERING

Level sensors for water treatment

Separate tank inventory measurement from high/low switching and chemical dosing duties.

MEDIA TO REVIEW

Service water, treated water, compatible wastewater and treatment chemicals

What the sensor needs to do

Sludge, scale or biological deposits may persist at the tip after a vessel has emptied.

LocationControl objectiveSelection focus
Service tanksHigh/low indication at fixed positions.Choose accessible mounting points.
Dosing systemsA low-level process permissive.Evaluate the dosing chemical separately from the water.
Small process skidsCompact material-presence feedback.Confirm the available pipe diameter and electrical interface.

Installation and integration

Keep the sensing tip out of a stagnant branch that remains full after the main pipe drains. In a dirty service, plan an isolation and cleaning method. If operators need a percentage or remaining volume, keep a suitable continuous transmitter in the design.

A representative test plan

Compare clean water, the expected treated or dirty water, drained residue and any cleaning chemical. Record both the sensor indicator and the PLC state. Simulate loss of power and a disconnected signal in a controlled commissioning procedure.

A common selection mistake

Using a low-mounted wetted sensor as proof that a pump has adequate suction head. Local presence does not establish flow, pressure or the absence of cavitation.

What to include in your inquiry

  • Water quality and expected deposits
  • Tank or pipe drawing with mounting position
  • Alarm or control action at high/low level
  • Maintenance access and required documentation

Choose a starting point

Review Lisen electronic point switches for a configured industrial package or Baumer CleverLevel families for a documented manufacturer selection. Selection depends on the exact medium, configuration and duty. A family name alone is insufficient to approve the application.

Technical references

Lisen technical reference — English summary of the supplied 2024-11-25 manual ↗

Baumer — CleverLevel point level sensor portfolio (reviewed 2026-10-03) ↗

Family information and engineering guidance are a starting point. Confirm the exact order-code documentation and installation requirements.

Go deeper

LISEN · BAUMER

Start with your process. We will help define the sensor.

Medium, temperature, pressure, connection and control task: these five details make an inquiry much more useful.

Request a quote