Skip to content
LISEN BAUMER · Point detection
◎ EN
Request a quote

APPLICATION ENGINEERING

Level switches for pharma & personal care

Combine application testing with the traceability and hygienic records required by your process.

MEDIA TO REVIEW

Compatible process liquids, gels, creams and personal-care formulations

What the sensor needs to do

A clean-looking probe and a material declaration alone do not establish suitability for a validated production process.

LocationControl objectiveSelection focus
Process vesselsDefined product-present or high/low states.Agree on the actual recipe and cleaning sequence.
Transfer linesPresence detection with limited intrusion.Review drainage and residual gel films.
Cleaning transitionsEvaluation of selected medium changes.Verify meaningful separation of the measured responses.

Installation and integration

Specify surface finish, seal design, connection standard and traceability requirements in the quotation. Check the complete mounted assembly against the plant requirements. Keep the electronics within the documented ambient limit during sterilization or high-temperature cleaning.

A representative test plan

Define an acceptance protocol before commissioning. Record the order code, serial number, parameter set, firmware where relevant, medium batch, temperature and switching results. Repeat after cleaning and document the approved restoration procedure after sensor replacement.

A common selection mistake

Using a certificate for a raw material to claim approval of the entire installed assembly, or promising a validation outcome before the plant reviews the records.

What to include in your inquiry

  • Recipe range and cleaning/sterilization duty
  • Hygienic connection and surface requirements
  • Material and batch traceability documents
  • Qualification, change-control and acceptance requirements

Choose a starting point

Review Lisen electronic point switches for a configured industrial package or Baumer CleverLevel families for a documented manufacturer selection. Selection depends on the exact medium, configuration and duty. A family name alone is insufficient to approve the application.

Technical references

Lisen technical reference — English summary of the supplied 2024-11-25 manual ↗

Baumer — CleverLevel point level sensor portfolio (reviewed 2026-10-03) ↗

Family information and engineering guidance are a starting point. Confirm the exact order-code documentation and installation requirements.

Go deeper

LISEN · BAUMER

Start with your process. We will help define the sensor.

Medium, temperature, pressure, connection and control task: these five details make an inquiry much more useful.

Request a quote
滚动至顶部