Skip to content
LISEN BAUMER · Point Level Sensor
◎ EN
Request a quote

Installation

Why maximum temperature and pressure cannot be combined

A correctly specified Point Level Sensor can serve a demanding pressure and temperature duty while preserving a compact local switching point.

4 10 月 2026 · 3 minute read

POINT LEVEL SENSOR / PRACTICAL ADVANTAGE

Use the available operating range with confidence

A correctly specified Point Level Sensor can serve a demanding pressure and temperature duty while preserving a compact local switching point. Reviewing the combined envelope helps identify the suitable version early. It also prevents a seemingly attractive maximum value from being mistaken for a universal operating condition.

Read the table by configuration

The supplied 2018 LBFS sheet distinguishes industrial, hygienic, cooling-neck and sliding versions. It does not describe one universal sensor meeting every maximum. For example, the standard industrial G½ reference and the high-temperature sliding reference have different pressure limits.

Include ambient temperature and duration

A temporary cleaning peak may be permitted for a limited duration and only under stated ambient conditions. A cooling neck or required projection length helps keep the electronics within limits. Do not remove that installation condition when summarizing a catalogue.

For Lisen, the supplied manual states a standard temperature range and mentions a high-temperature option. The optional maximum requires a confirmed construction and operating envelope, not an assumption that every standard sensor can use it.

Specify the worst credible combinations

Ask for a matrix covering normal operation, cleaning, startup and the relevant upset cases. Each row should include temperature, pressure, duration and medium. Have the supplier identify whether the offered sensor, connection, seal and accessories satisfy each row together.

What to confirm for your application

  • Exact order code and construction
  • Concurrent temperature and pressure
  • Peak duration and ambient conditions
  • Connection and seal limits
  • Approved drawing and operating envelope

Create an operating-state table

Catalogue maxima describe the scope of a family, while a purchasing decision needs the permitted combinations for one configuration. Connection geometry, seals, probe extension and cooling arrangements can change the limits. Ask for the current drawing and operating envelope and compare every row of the duty table against them. If a point falls outside the documented envelope, do not resolve it by averaging the conditions. Request a different configuration or a documented engineering assessment. Keep process temperature separate from the allowable ambient temperature at the electronics.

Review item Meaning Action
Production Temperature, pressure and duration Use normal and credible maximum conditions.
Cleaning / sterilization Temperature, chemical, pressure and exposure time A short permissible excursion is not a continuous rating.
Shutdown / cool-down Vacuum and ambient conditions Include thermal and pressure transitions.

Explore the Point Level Sensor advantages guide or compare the available sensor families for this duty.

Put this Point Level Sensor advantage to work

Compare the Lisen and Baumer Point Level Sensor families, prepare an application brief, or use the sensor selector to organize the next technical discussion.

References

Baumer CleverLevel LBFS datasheet — supplied reference, EN/2018-03-01

Lisen technical reference — English summary of the supplied 2024-11-25 manual

Technical guidance. Verify the current order-code documentation and your plant requirements before applying a recommendation.

Continue reading

LISEN · BAUMER

Put Point Level Sensor advantages to work in your process.

Tell us the medium, switching task, temperature, pressure and connection. We will help define the sensor family and installation package.

Request a quote
Contact on WhatsApp
滚动至顶部