Less intrusion into the process
A short sensing tip suits compact vessels and pipes. Check insertion depth, nozzle geometry and cleaning access.
LISEN · BAUMER
Compact electronic point level switches with PEEK sensing tips. Specify output, connection and process conditions for a configured quotation.
OUR OWN BRAND
Compact electronic point level switches with PEEK sensing tips. Specify output, connection and process conditions for a configured quotation.
Request the process adapter, seal, M12 cable and electrical interface with the sensor. Confirm every supplied item in the quotation; accessories and certificates are not automatically included.
| Parameter | Reference value |
|---|---|
| Supply voltage | 12–30 V DC |
| Switching output | PNP / NPN |
| Maximum output current | 20 mA |
| Process temperature | −40…+115 °C |
| Process pressure | −0.1…10 MPa (−1…100 bar) |
| Wetted materials | PEEK + 316L / Ti (Option dependent) |
| Ingress protection | IP67 |
| Process connection | G ½ (Standard configuration) |
| Electrical connection | M12 · 4-pin |
| Sensing position tolerance | ±5 mm |
Values follow the supplied Lisen manual dated 2024-11-25. High-temperature versions up to 200 °C and custom probes up to 250 mm require separate confirmation. Maximum temperature and pressure must not be combined without an approved operating envelope.
The manual states a typical supply current of 8 mA and a maximum of 40 mA. This is separate from the 20 mA maximum switching load. A PLC input or a suitably designed interface is required; the sensor must not drive a pump motor or solenoid directly.
The source manual identifies a G½ connection, M12 four-pin connector and a nominal 99 mm overall drawing length. A high-temperature construction, extended probe, titanium wetted part or alternative process connection is a separate configuration. Request its drawing and simultaneous pressure/temperature limits with the offer.
The supplied material reports are supporting records, not blanket certification of every assembled sensor. Ask for batch traceability and destination-specific documentation where needed.
Technology comparison
A compact sensing tip and no moving float can simplify installation. Performance still depends on the medium, mounting position and settings.
A short sensing tip suits compact vessels and pipes. Check insertion depth, nozzle geometry and cleaning access.
Evaluate product, foam and residue separately. Difficult media may need a sample test and adjusted switching thresholds.
Confirm the sensor, mounting adapter, seal, cable and PLC input together. A matching thread alone does not ensure interchangeability.
Downloads
Sample demonstrations show only the recorded test conditions. Confirm suitability with your own medium and operating conditions.
LISEN · BAUMER
Medium, temperature, pressure, connection and control task: these five details make an inquiry much more useful.