Why a point sensor with 4–20 mA is not a tank level transmitter

Some Point Level Sensor versions provide additional analog information alongside the switching task.

4 10 月 2026 · 2 minute read

POINT LEVEL SENSOR / PRACTICAL ADVANTAGE

Add process information at the point of detection

Some Point Level Sensor versions provide additional analog information alongside the switching task. That can help interpret media changes at the probe when the selected device supports it. It does not turn a short local probe into a continuous tank-level transmitter; specify the meaning of the output explicitly.

Separate interface from measurand

The phrase 4–20 mA describes a signal range. To interpret it, identify the measured variable, units, scaling and sensor geometry. A local probe near one nozzle sees its immediate surroundings. Wiring that signal to an analog input does not give the probe visibility of the whole tank.

A simple counterexample

Imagine a sensing tip installed 0.30 m above the bottom of a 2 m tank. With the same liquid fully covering the tip, the tank could contain a surface at 0.50 m or 1.80 m. Unless the specified sensing principle measures that change in surface position, a local covered response cannot distinguish those two heights. Scaling the PLC display from zero to 100 percent would therefore create an unsupported level indication.

A numerical sensor response can still be useful. It can help observe differences between validated local process states or reveal changes that deserve investigation. This usefulness is separate from continuous level measurement.

Check what the actual PL20 version provides

Baumer lists a digital push-pull output and a 4–20 mA output for the specific PL20S-11534.133013.G07020020000 product page. That is evidence for that variant, not a promise about every PL20 or legacy LBFS. Obtain its current manual to establish the assigned analog variable, configuration, pinout and fault behavior.

Choose the correct instrument for inventory

If the requirement is changing surface height, volume or inventory, evaluate a continuous-level measurement system and the vessel geometry. If the requirement is a high or low permissive, evaluate a point switch. Both may be useful in one installation, but their signals should be named accurately in the PLC and operator display.

What to confirm for your application

  • Measured variable, units and scaling
  • Exact variant and supported operating mode
  • Pinout and analog-input compatibility
  • Fault indication and displayed engineering units
  • Whether inventory or only local presence is required

Explore the Point Level Sensor advantages guide or compare the available sensor families for this duty.

Put this Point Level Sensor advantage to work

Compare the Lisen and Baumer Point Level Sensor families, prepare an application brief, or use the sensor selector to organize the next technical discussion.

References

Baumer — PL20S-11534.133013.G07020020000, product-specific technical data

Endress+Hauser — Basics of continuous level measurement

Technical guidance. Verify the current order-code documentation and your plant requirements before applying a recommendation.

Continue reading

LISEN · BAUMER

Put Point Level Sensor advantages to work in your process.

Tell us the medium, switching task, temperature, pressure and connection. We will help define the sensor family and installation package.

Request a quote
Contact on WhatsApp
滚动至顶部